Details
+++ I. Storage System, 2 Drawers Wide +++
Storage system for blowing machine mobile, 2 drawers, fully assembled
Sturdy built-in drawer cabinet made of multiplex board (screen printing plate) for vacuum barrel, accessories, and tools (lockable), base for hose reel and pre-installation for integration of the suction solution.
Consisting of:
-Trailer: Compact cabinet module for accessories (wide, 850mm) (Item No. 11379)
-Required small parts + labor for installation in a blowing machine mobile/container
-----------------------------------------------------------------------------------------------------
+++ II. Extraction System +++
Extraction system (Item No. 6566)
Professional solution for quick switching between blowing and suction operation of a blowing machine or booster/extraction station, consisting of:
-Revolver diverter valve with 2 inlets and 3 outlets, securely fastened for transport in the blowing machine mobile
-115l vacuum barrel
-5 woven polypropylene collection bags
-
Hoses and clamps for connection to a blowing machine
-
Ready-to-operate connection to a blowing mine
---------------------------------------------------------------------------------------------------
+++ III. Hose Storage + Hose Setup +++
Hose storage (Item No. 6565)
Professional solution for practical winding and storage of hoses up to 110m in length (depending on hose diameter), consisting of:
-
Hose reel D1000 plus, securely fastened or strapped for transport in the blowing machine mobile
-
Swivel connector, connecting hoses and clamps for connection to a blowing machine
-
Ready-to-operate connection to a blowing machine
-
Ready-to-operate hose setup (suction hoses, etc.) (Item No. 6)
-
Ready-to-use hose system for a blowing machine mobile, consisting of:
2 hrs service: skilled labor cost for technician (Item No. 418)
---------------------------------------------------------------------------------------------------
+++ IV. EMB: Electrical Installation +++
Electrical installation 400V-16A / 230V-16A, all-current sensitive (incl. installation in blowing machine mobile) (Item No. 9352)
Professional electrical pre-installation 400V-21A incl. all-current sensitive residual current device (RCD type B) for blowing machine mobile, incl. 3 LED indicators each for main and auxiliary connections (1 LED per phase), switch for lighting, Schuko socket (max. 50W), 2 wall-mounted CEE device plugs, 2 surface-mounted CEE sockets, automatic circuit breakers, completely installed.
Consisting of:
-Electrical installation 400V-16A / 230V-16A all-current sensitive (Item No. 9352)
-
All-current sensitive RCD 40A
Power adapter 400V/16A, 10m ring, CEE (Item No. 348, may be shortened or extended)
-Power adapter 230V CEE-CEE L 10m ring (Item No. 1483, may be shortened or extended)
-Device plugs input 400V/16A and 230V/16A
- Incl. all necessary small parts, fully installed and ready to use
Explanations:
The safe operation of blowing machines with frequency-controlled drives and a 400V/16A connection requires connection to a power source equipped with an all-current sensitive residual current device (RCD) of type B or B+. If the available power source is not appropriately equipped (e.g. no RCD or only RCD type A) or if the type of RCD is unknown, this power distributor ensures safe operation.
Fault currents with smooth DC components, as may occur in frequency-controlled machines, can be monitored in this way without additional protective measures at the power source.
Background: current regulations for commercial work on construction sites, such as DGUV Information 203-006 (BGI608), IEC61439, IEC 62262 and recognized technical standards, which are described in more detail e.g. in VDE 0100-704.
---------------------------------------------------------------------------------------------------
+++ V. Interior Lighting +++
Interior lighting (Item No. 7291), only available in combination with electrical p