Thickness gauge for determining installation thickness with open blowing of insulation material (in-situ formed loose fill cellulose -LFCI- and mineral wool -MW) according norm EN15101 and EN14064, consisting of:
- Test panel approx. 80g
- Test rod, L approx. 500mm
Notes:
- Smooth out any unevenness
- Insert the test rod through the test panel, so there is a maximum distance between the test panel and the test probe
- Pierce the test rod to the bottom of the insulation layer
- Carefully lay the test panel on the insulation layer
- Let the weight of the test panel rest
- Measure the length of the test rod from the test probe to the test panel
- Repeat the test in different areas of the insulation (for example in 10 different places), calculate the average